Contact Us

Home > Products

poland 2500kva 11kv rectifier traction transformer winding

Just fill in the form below, click submit, you will get the price list, and we will contact you within one working day. Please also feel free to contact us via email or phone. (* is required).

  • S13-M 11kV/0.4kV 30KVA-2500KVA Oil Immersed Transformer ...

    22 rowsu2002·u20022019-9-29u2002·u2002S13 Oil immersed power transformer is an independently developed product basing on the original S11 distribution transformer by research …

    Get Price
  • S11-M 11kV/0.4kV 30KVA-2500KVA Oil Immersed Transformer ...

    2019-9-29u2002·u2002S11-M 11kV/0.4kV 30KVA-2500KVA Oil Immersed Transformer-Winding Series. September 29, 2019. yucaihui ...

    Get Price
  • RECTIFIER TRANSFORMERS IN ELECTRIC TRACTION

    2004-11-4u2002·u2002The traction network in Poland is supplied with dc voltage. The transformer-rectifier sets present in traction substations transform ac voltage supplied from a power grid into appropriate dc voltage. The simplest version of such appliance consists of a recti-fier transformer and a rectifier. Additionally, series

    Get Price
  • 11kV Transformers

    2019-2-1u2002·u200211kV Transformers. Powerstar SO-LO range of super low loss transformers are the only amorphous core transformers designed and manufactured in the UK and provide a cost-effective way of reducing energy consumption by upgrading high voltage (HV) infrastructure up to 11kV. Distribution transformers have been at the heart of the energy network, and ...

    Get Price
  • Transformer Design & Design Parameters

    2014-12-8u2002·u2002•Tertiary voltage generated at buried TV winding has no importance for user; typically such TV winding is delta connected and provides the path for zero-sequence currents during short-circuit and suppresses third harmonic (and its multiples) currents. Transformer Consulting Services Inc. Transformer Design: Tertiary Voltage (TV)

    Get Price
  • Transformers - Hitachi ABB Power Grids

    2021-9-15u2002·u2002Transformers. Hitachi ABB Power Grids is global leader in transformers, offering liquid-filled and dry-type transformers as well as services for complete life-cycle support, including replacement parts and components. Our portfolio allows utilities, industries and infrastructure sectors to maximize return on transformer assets by ensuring high ...

    Get Price
  • Traction Power Supply ABB traction rectifiers Diode ...

    2021-2-15u2002·u2002750V,4000A rectifier with non standard DC out through sidewall 10 ABB traction rectifiers Protection The rectifier-transformer set is protected against short circuit at the DC output by MV circuit breaker. It is the main protection of the unit. Protection against overload is provided by external protective relay which is a part of MV breaker.

    Get Price
  • 2MVA, 5MVA, 10MVA Transformers, 11KV Transformers, 33KV ...

    2021-4-3u2002·u2002A rectifier transformer circuit permitting six-phase double-wye operation with 120.degree. conduction, (without the use of an inter phase transformer), and providing any predetermined degree of phase shift. The transformer comprises a zigzag wye primary winding and a six-phase star secondary winding.

    Get Price
  • CAST RESIN TRANSFORMERS - Legrand

    2017-12-4u2002·u2002CAST RESIN TRANSFORMERS SELECTION CRITERIA 5 Legrand is one of the most important producers of cast resin transformers. Thanks to a long experience in the production of cast resin transformers up to 36 kV and constant investment

    Get Price
  • 25mva 66kv Double-Winding Power Transformers with off ...

    Product Introduction. This 5 MVA power transformer was delivered to South Africa in 2015, it's a step down transformer 33kv to 11kv, the primary voltage is 33kv, the secondary voltage is 11kv, the transformer is equipped with no load tap changer, the tapping range is ±2*2.5% at primary side, the cooling is ONAN, our 5 MVA power transformer was designed with advanced technology and …

    Get Price
  • S13-M 11kV/0.4kV 30KVA-2500KVA Oil Immersed

    2019-9-29u2002·u2002S13 Oil immersed power transformer is an independently developed product basing on the original S11 distribution transformer by research application of new material and new process and combing self-dependent innovation with technology import and optimal innovation design of iron core and coil structure to reduce no-load loss and noise.

    Get Price
  • S11-M 11kV/0.4kV 30KVA-2500KVA Oil Immersed

    2019-9-29u2002·u2002S11-M 11kV/0.4kV 30KVA-2500KVA Oil Immersed Transformer-Winding Series. September 29, 2019. yucaihui ...

    Get Price
  • RECTIFIER TRANSFORMERS IN ELECTRIC TRACTION

    2004-11-4u2002·u2002The traction network in Poland is supplied with dc voltage. The transformer-rectifier sets present in traction substations transform ac voltage supplied from a power grid into appropriate dc voltage. The simplest version of such appliance consists of a recti-fier transformer and a rectifier. Additionally, series

    Get Price
  • 11kV Transformers

    2019-2-1u2002·u200211kV Transformers. Powerstar SO-LO range of super low loss transformers are the only amorphous core transformers designed and manufactured in the UK and provide a cost-effective way of reducing energy consumption by upgrading high voltage (HV) infrastructure up to 11kV. Distribution transformers have been at the heart of the energy network, and ...

    Get Price
  • Transformer Design & Design Parameters

    2014-12-8u2002·u2002•Tertiary voltage generated at buried TV winding has no importance for user; typically such TV winding is delta connected and provides the path for zero-sequence currents during short-circuit and suppresses third harmonic (and its multiples) currents. Transformer Consulting Services Inc. Transformer Design: Tertiary Voltage (TV)

    Get Price
  • Transformers - Hitachi ABB Power Grids

    2021-9-15u2002·u2002Transformers. Hitachi ABB Power Grids is global leader in transformers, offering liquid-filled and dry-type transformers as well as services for complete life-cycle support, including replacement parts and components. Our portfolio allows utilities, industries and infrastructure sectors to maximize return on transformer assets by ensuring high ...

    Get Price
  • Traction Power Supply ABB traction rectifiers Diode ...

    2021-2-15u2002·u2002750V,4000A rectifier with non standard DC out through sidewall 10 ABB traction rectifiers Protection The rectifier-transformer set is protected against short circuit at the DC output by MV circuit breaker. It is the main protection of the unit. Protection against overload is provided by external protective relay which is a part of MV breaker.

    Get Price
  • 2MVA, 5MVA, 10MVA Transformers, 11KV Transformers,

    2021-4-3u2002·u2002A rectifier transformer circuit permitting six-phase double-wye operation with 120.degree. conduction, (without the use of an inter phase transformer), and providing any predetermined degree of phase shift. The transformer comprises a zigzag wye primary winding and a …

    Get Price
  • CAST RESIN TRANSFORMERS - Legrand

    2017-12-4u2002·u2002CAST RESIN TRANSFORMERS SELECTION CRITERIA 5 Legrand is one of the most important producers of cast resin transformers. Thanks to a long experience in the production of cast resin transformers up to 36 kV and constant investment

    Get Price
  • 25mva 66kv Double-Winding Power Transformers with off ...

    Product Introduction. This 5 MVA power transformer was delivered to South Africa in 2015, it's a step down transformer 33kv to 11kv, the primary voltage is 33kv, the secondary voltage is 11kv, the transformer is equipped with no load tap changer, the tapping range is ±2*2.5% at primary side, the cooling is ONAN, our 5 MVA power transformer was designed with advanced technology and adopts ...

    Get Price
  • TRACTION POWER TRANSFORMERS

    2020-10-6u2002·u2002Tyr ee is the only Australian transformer manufacturer producing in-house, customised winding conductors including tensile rated and tested high conductivity copper conductors, coated and wrapped to specific design and performance. These techniques and technologies are particularly relevant to traction duty transformers subject to frequent

    Get Price
  • Transformers - GE Grid Solutions

    2014-1-31u2002·u2002XD GE. Rectifier transformers can be supplied with ratings ranging from 35kV . to 220kV, and up to 140MVA, some of the largest in the world. Various transformer configurations are available, including: • On-load or off-load tap changers • Three phase bridge-type rectifier • Double Delta-star three phase, five-leg rectifier transformer

    Get Price
  • Refurbished Transformers – Slaters Electricals

    UK's Largest Stock of Refurbished Transformers. As the UK's leading supplier of refurbished transformers, we have over 300 used power, distribution, cast resin & low voltage transformers in stock. We hold transformers in stock from quality manufacturers such as ABB, Brush, Merlin Gerin, Pauwels, Schneider, Siemens & South Wales.

    Get Price
  • Power transformers - Hitachi ABB Power Grids

    2021-9-14u2002·u2002Transformer designs and materials used are constantly changing with changing materials prices. Hitachi ABB Power Grids can also provide transformers according to Tier 2 loss requirements and even lower losses. Hitachi ABB Power Grids is the leading manufacturer for ultra-efficient transformers, as a company being itself fully dedicated to ...

    Get Price
  • Dry type transformers for safety, reliability and ...

    2019-4-2u2002·u2002UL certified transformer, ANSI C57.12 & IEEE Standard, with On Load Tap changer. Widest portfolio. Abilities include a full line of LV magnetics, MV transformers for distribution and rectifier duty, MV iron and air core reactors, as well as the first ever dry-type transformer for sub-transmission. From 10 kVA up to 63 MVA; From 220 V up to 72.5 kV

    Get Price
  • ABB Power Transformers - Latest Price, Dealers & Retailers ...

    Call +91-8042958443. Contact Supplier Request a quote. Abb Dry Transformer In Stock. ₹ 7 Lakh Unit. Get Quote. 2500KVA ABB Power Transformer. ₹ 12 Lakh Unit Get Latest Price. Power Rating: 2500KVA. Cooling Type: Air Cooled.

    Get Price
  • Dry-type transformers - Hitachi ABB Power Grids

    2021-9-14u2002·u2002Dry-type Transformers. Hitachi ABB Power Grids offers a full range of dry-type transformers with primary voltages through 72.5 kV built according to all major standards including IEC and ANSI. To minimize environmental contamination and fire hazard, customers are specifying dry-type transformers more frequently. These transformers meet strict ...

    Get Price
  • Flyback transformer design considerations for efficiency ...

    2018-6-16u2002·u2002The flyback transformer is not really a transformer in the conventional sense; it is actually a coupled inductor. Figure 1 is a simplified schematic of a flyback converter. The flyback transformer in this example has three windings: primary, secondary and bias (sometimes called the auxiliary winding). AC/DC power supplies widely use the flyback

    Get Price
  • Jayesh Electricals Limited

    2018-1-27u2002·u2002Jayesh Electricals Ltd. is founded on a vision which seeks to usher in a better tomorrow for global citizens. From humble beginnings almost two decades back, Jayesh Electricals Ltd. has today grown into a nationally respected and known Distribution & Power Transformer manufacturing company.

    Get Price
  • Application of Dry Type Power Transformer in the Future ...

    (1) Energy-saving and low-noise: With in-depth study of new low-cost silicon steel sheets, foil winding structure, stepped iron core joints, environmental protection requirements, noise, and the introduction of new materials, processes and technologies such as computer optimization design, the dry type power transformer in the future is more energy-efficient and quieter.

    Get Price
  • TRANSFORMER RECTIFIER UNITS - Jeppesen

    2018-9-15u2002·u2002Figure 11.10 – Transformer rectifier unit The TRU that is fitted to an aircraft is typically supplied with 115 V 400 Hz three-phase AC, which is stepped-down through a three-phase star-star wound transformer and changed to 28 VDC by a six-rectifier bridge assembly. The output from the TRU is then fed to the aircraft's DC busbars.

    Get Price
  • Dry type power transformers for sale, dry type transformer ...

    2017-12-8u2002·u2002Dry transformer is mainly applied to heating furnace such as glass furnace, electric resistance furnace, vacuum furnace, polycrystalline furnace etc and electroplate, traction rectifier transformer for first grade. SCB9 Series 11kv Cast Resin Two-winding Dry Type Transformer

    Get Price
  • Flyback transformer design considerations for efficiency ...

    2018-6-16u2002·u2002The flyback transformer is not really a transformer in the conventional sense; it is actually a coupled inductor. Figure 1 is a simplified schematic of a flyback converter. The flyback transformer in this example has three windings: primary, secondary and bias (sometimes called the auxiliary winding). AC/DC power supplies widely use the flyback

    Get Price
  • Dry Type Transformer Brochure - Eaton

    2021-9-9u2002·u2002《IEC60076 Power Transformer 》 Customizable according to special customer demands. 10kV 630kVA Level 10 LV foil-type winding Resin-insulated dry-type transformer Three-phase S C B 10 630 10 High-voltage Level(kV) Rated Capacity Level(kVA) Code of performance level (Design code) LV foil-type winding Resin-insulated dry-type transformer

    Get Price
  • MULTI PULSE RECTIFIER USING DIFFERENT PHASE

    2016-4-23u2002·u2002Phase shifting transformers are classified in two categories: Y/Z and Δ/Z where the primary winding can be connected in to Y or Δ where the secondary winding is normally connected in Z. Both configurations can be equally used in multi pulse rectifier. And also other transformer connections can be used in multi pulse

    Get Price
  • VFD transformers: Clock number and vector group - MB Drive ...

    2020-5-1u2002·u2002Example 2 is a typical transformer for 12-pulse rectifier. Example 2: Yy0d1. Three-winding transformer has vector group Yy0d1. Primary HV winding is again star (wye) connected. One secondary winding is star connected without any phase displacement towards primary. Other secondary winding is delta connected and 30 degree lagging with respect to ...

    Get Price
  • Transformer Winding Resistance Testing Explained

    2018-3-18u2002·u2002Use Caution When Testing. Before conducting a transformer winding resistance test, it is important to observe all safety warnings and take proper precautions.Ensure that all equipment to be tested is properly grounded and treat all high-voltage power equipment as energized until proven otherwise by using the proper lockout/tagout procedures.

    Get Price
  • Winding Resistance Test Of Transformer - Electrical ...

    The measuring current can not be over 15% of the rated current of the tested winding; The measuring current should be selected within the range of the testing resistance as stipulated by instrument; The tester for the DCR of transformer: 5A 1mΩ—4Ω. 10A 0.2mΩ—2Ω. 20A 0.1mΩ—1Ω. The measurement of winding resistance.

    Get Price
  • Dry Type Transformer, Indoor And Outdoor, 11kv To 33kv ...

    Dry Type Cast Coil Resin Transformers from 100KVA to 10MVA upto 33KV. We can offer ABB retrofit solutions for old switch boards. These solutions are easy, time consuming and economical. Relays for Distribution and Transmission. Relay retrofit solution. Control terminations for Transformer and Braker installations in switch yards.

    Get Price
  • CG Distribution Transformers - CG 315 to 3000 kVA Cast ...

    CG Power Systems cast resin transformers are ideally suited for environments that demand the highest level of safety. Used widely in diverse settings – from office and apartment buildings, to hospitals, underground transport systems, and industrial and off-shore installations – the CG Power Systems cast resin transformers have a proven track record for reliability and high-performance.

    Get Price
  • multi-winding phase-shifting rectifier transformers

    2020-4-26u2002·u2002In line with market demand, ZTELEC has successfully developed multi-winding phase-shifting rectifier transformers based on the leading non-encapsulated dry-type transformer technology. The multi-winding phase-shifting rectifier transformer is designed according to the user and has a capacity of 250~2500kVA.

    Get Price
  • CALCULATION OF ESDD-02-006 SYSTEM FAULT LEVELS

    2017-8-9u2002·u2002transformer winding and earthing arrangements, a single phase to earth fault may result in more current in the faulted phase than would flow in each of the phases for a balanced 3 phase fault at the same location. It is often the case, particularly at 132kV and 275kV that single phase faults are more severe than 3-phase faults. 8.1.3 X/R Ratio

    Get Price
  • Refurbished Transformers – Slaters Electricals

    UK's Largest Stock of Refurbished Transformers. As the UK's leading supplier of refurbished transformers, we have over 300 used power, distribution, cast resin & low voltage transformers in stock. We hold transformers in stock from quality manufacturers such as ABB, Brush, Merlin Gerin, Pauwels, Schneider, Siemens & South Wales.

    Get Price
  • COMPANY PROFILE - matlakse.co.za

    2021-2-1u2002·u2002Rectifier Transformers, 7. Traction Transformers, 8. Power Transformers, 9. Dry Type Transformers, 10. ARC Furnace Transformers, ... transformer with only one winding. The winding has at least 3 taps where ... known engines and alternators ranging from 14.5 - 2500kVA.

    Get Price
  • Varelen Electric Co., Ltd

    We specialize in manufacturing various kinds of cast resin transformers, distribution transformers, VPI dry type transformers, phase shift transformer and substations. Dedicated to Comprehensive performance testing, strict quality control and thoughtful customer service, our experienced staff members are always available to discuss your requirements and ensure full customer satisfaction.

    Get Price
  • MULTI PULSE RECTIFIER USING DIFFERENT PHASE

    2016-4-23u2002·u2002Phase shifting transformers are classified in two categories: Y/Z and Δ/Z where the primary winding can be connected in to Y or Δ where the secondary winding is normally connected in Z. Both configurations can be equally used in multi pulse rectifier. And also other transformer connections can be used in multi pulse

    Get Price
  • VFD transformers: Multi-winding design - MB Drive Services

    2019-11-12u2002·u2002Purpose of multi-winding design. One purpose of multi-winding VFD transformer is to minimize the harmonics of VFD injected into the grid. This is achieved by using rectifiers with higher pulse number (most common 12-pulse, 18-pulse, 24-pulse, 30-pulse or 36-pulse) in combination with corresponding phase shifting input transformer.

    Get Price
  • transformers winding Tender News

    Tender For For necessary repairing, Dehydration, filtration, installation & commissioning of Buclchoz relay, winding meter, oil temperature meter in 2 MVA 11KV 3.3 KV power transformer at R.J. unit of Bahula Colliery under Kenda Area. for monsoon preparation View Tender Detail : …

    Get Price
  • Types of Transformer Windings: Cylindrical, Helical ...

    2012-2-24u2002·u2002We use helical windings low voltage, high capacity transformers, where the current is higher, at the same time windings turns are lesser. The output of the transformer varies from 160 – 1000 kVA from 0.23-15 kV. To secure adequate mechanical strength the cross-sectional area of the strip not made less than 75-100 mm square. The maximum number of strips used in parallel to …

    Get Price
  • Rectifier Transformer - Working Principle and Application

    A Rectifier transformer is a special application transformer which includes diodes and thyristors in the same tank. Power electronic circuits that convert alternating current (ac) to direct current (dc) is called rectifier circuits. Similarly, the circuits which can convert direct current to alternating current are called inverter circuits.

    Get Price
  • Liquid-filled power transformers - ABB

    2021-2-15u2002·u2002Liquid-filled power transformers 7 Helical layer winding Disc winding Windings Transformer windings are the most critical part of the transformer. They decide about major transformer parameters which must suit to the customer specification and all related standards. Winding design has to take into consideration nominal power, voltage ratio,

    Get Price
  • Computation of Rectifier Transformers employed in

    transformers are used to provide DC for traction, usually stepping down from medium voltage levels. Mineral oil is essential for optimised performance of large transformers, providing the much needed cooling at high power operation and elevated core and winding temperatures. A representative rectifier transformer has been modelled for

    Get Price
  • CALCULATION OF ESDD-02-006 SYSTEM FAULT LEVELS

    2017-8-9u2002·u2002transformer winding and earthing arrangements, a single phase to earth fault may result in more current in the faulted phase than would flow in each of the phases for a balanced 3 phase fault at the same location. It is often the case, particularly at 132kV and 275kV that single phase faults are more severe than 3-phase faults. 8.1.3 X/R Ratio

    Get Price
  • Transformer resistance testing - Megger

    By measuring a transformer's winding resistance from one HV transformer bushing to another, transformer resistance testing can reveal a great deal of information about the transformer. In addition to the obvious faulted transformer winding (i.e., an open winding or …

    Get Price
  • Converter Duty Transformer, Dry (VPI) and (CRT ...

    2021-4-8u2002·u2002A rectifier transformer circuit permitting six-phase double-wye operation with 120.degree. conduction, (without the use of an inter phase transformer), and providing any predetermined degree of phase shift. The transformer comprises a zigzag wye primary winding and a six-phase star secondary winding.

    Get Price
  • What is a Double Winding Transformer - YueBian Electric

    Therefore, the double winding transformer can be divided into two types: step-up transformer and step-down transformer. Most of the double winding transformers have fixed iron core, on which there are primary and secondary coils. Based on the high conductivity of iron, most of …

    Get Price
  • Atlas Transformers India

    2021-2-9u2002·u2002Atlas Transformers India is founded on a vision which seeks to usher in a better tomorrow for global citizens. From humble beginnings almost two decades back, Atlas Transformers India has today grown into a nationally respected and known Distribution & Power Transformer manufacturing company.

    Get Price
  • BRUSH

    BRUSH has been a key figure within Electrical Engineering for over 130 years, offering a wide range of 'electrical machines', and providing our customer chain with the highest calibre equipment and after sales service. This unrivalled offering includes Turbo Generators, Synchronous Condensers, Motors, Power Transformers, MV Switchgear and ...

    Get Price
  • Understanding Vector Group of Transformer (part 1)

    2021-7-27u2002·u2002Understanding Vector Group of Transformer (Part 1) The primary windings are connected in one of several ways. The two most common configurations are the delta, in which the polarity end of one winding is connected to the non-polarity end of the next, and the star, in which all three non-polarities (or polarity) ends are connected together.

    Get Price
  • ABB PCM600 – Electrical Engineering

    2021-8-22u2002·u2002– Transformer 10MVA,66/11KV HV side CT ratio 125/1A LV side CT ratio 800/1 A Relay Micom P642 – Settings of harmonic – If I'm not wrong, in modern transformers because of core material, the Inrush current harmonics are sometimes less than 20% of the fundamental frequency component due to which differential relay operates.

    Get Price
Contact Us