italy pad mounted transformer impedance table

Just fill in the form below, click submit, you will get the price list, and we will contact you within one working day. Please also feel free to contact us via email or phone. (* is required).

  • Distribution Transformer Impedance and Fault CurrentsExplore further

    2018-4-13u2002·u2002Short Circuit Current Table for 1Ø Transformers: 1Ø Transformer kVA Rating Secondary Volts Pad-Mounted Overhead Impedance (%) Fault Current Amps Impedance (%) Fault Current Amps 15 120 240 1.78 1.30 7,006 4,808 2.13 1.55 5,876 4,032 25 120 240 1.78 1.30 11,677 8,013 1.92 1.40 10,843 7,440 37.5 120 240 2.11 1.50 14,819 10,417 2.09 1.49 14,919 ...

    Get Price
  • Eaton Pad-mounted Transformer

    2021-9-14u2002·u2002PAD DIMENSIONS 3.5' I-3 CABINET/TANK DIMENSIONS Figure 2. Transformer and pad dimensions. * Add 9' for Bay-O-Net fusing. Table 8. 1Fluid-Filled—Copper Windings 55/65 °C Rise 1 Weights, gallons of fluid, and dimensions are for reference only and not for construction. Please contact Eaton for exact dimensions. * Add 9' for Bay-O-Net fusing.

    Get Price
  • Table 3.2.1 Typical Transformer Impedances (Tables (a)

    2018-5-18u2002·u2002ELECTRICAL POWER SYSTEMS ENGINEERING Table 3.2.1 Typical Transformer Impedances (Tables (a) and (b)) reprinted with permission from Electrical Transmission and Distribution Reference Book, ABB Power T&D Co., Raleigh, NC. (a) Standard Reactances and Impedances for Ratings 500 KVA and below (for 60 cycle Transformers).

    Get Price
  • Single Phase Pad Mounted Distribution Transformer

    2013-2-15u2002·u2002ERMCO single phase pad mounted distribution transformers are designed and manufactured in compliance with all applicable ANSI and RUS standards. All transformers are oil filled, 65˚C rise, and designed for usual service conditions per ANSI C57.12.00.

    Get Price
  • TRANSFORMER SECONDARY FAULT CURRENTS TABLES

    2017-8-31u2002·u2002Where one transformer is larger than the others in the bank, use the fault current value for the larger transformer. Pad Mounted Transformers Three Phase Padmounts Size (KVA) Impedance (%) Voltage (Ph-Ph) Sym Fault Current (Amps) 75 1.80 208 11,566 150 1.80 208 23,131 300 1.80 208 46,262 500 3.00 208 46,262 750 5.32 208 39,131

    Get Price
  • Eaton's Cooper Power Systems catalog Pad-mount ...

    front pad-mounted transformer. The low profile design blends visually with surroundings-shrubs, low hedges, and home air conditioners—making it ideal for residential applications. The MaxiShrub transformer from Eaton's Cooper Power Systems is an ANSI ® and IEEE Type-1 single-phase dead-front pad-mounted transformer.

    Get Price
  • Transformer Design & Design Parameters

    2014-12-8u2002·u2002Transformer Design: Short-circuit impedance •Current carrying conductors in a magnetic field experience force in accordance with Fleming's left hand rule. •Axial flux produces radial force and radial flux produces axial force •Conductors are attracted to each other when currents are

    Get Price
  • pad mounted transformer impedance - Electric power ...

    2010-3-21u2002·u2002I donot know from which ANSI standard you have sid that a 300 kVA pad mounted transformer shall have only 4% impedance.In fact the relevant IEEE std is IEEE C57.12.26 which specifies the impedance can be between 1.2-6.0.Therefore, if your short circuit results are ok with 4.42% then there cannot be a problem.

    Get Price
  • SHORT CIRCUIT FAULT CALCULATIONS

    2003-8-19u2002·u2002Table 1- Transformer Impedance Data Percent R, X and Z based on Transformer KVA Note 1: These values are for three phase, liquid filled, self-cooled transformers. Note 2: Due to the trend toward lower impedance transformers for better voltage regulation, the actual transformer impedances may deviate from the NEMA Standard given at left.

    Get Price
  • Technical Specifications for 500kVA Three Phase Dead

    2021-3-15u2002·u2002Technical Specifications for Three-Phase Pole Mounted Distribution Transformers Rev2 Guyana Power & Light Inc. Page 8 of 31 5. TRANSFORMER RATING The transformers shall be double wound, sealed type, oil immersed with natural oil and air-cooling (ONAN), three phase (3φ), pad-mounted with ratings of 500 kVA.

    Get Price
  • TRANSFORMER SECONDARY FAULT CURRENTS TABLES

    2017-8-31u2002·u2002Where one transformer is larger than the others in the bank, use the fault current value for the larger transformer. Pad Mounted Transformers Three Phase Padmounts Size (KVA) Impedance (%) Voltage (Ph-Ph) Sym Fault Current (Amps) 75 1.80 208 11,566 150 1.80 208 23,131 300 1.80 208 46,262 500 3.00 208 46,262 750 5.32 208 39,131

    Get Price
  • Transformer cheat sheet - ABB

    2013-12-23u2002·u2002GE Transformer Currents for Substation & Pad Mount Transformers Simple Calculations Detailed Calculations Transformer Tables Go To Simple Calculations Go To Main Sheet Primary Short circuit Amps = X/R1 = Are you assuming Infinite Source? Source Data Transformer Data Source Impedance Calculation (%Z1): X/R2 = 2.0 x rated motor load current at ...

    Get Price
  • Three-Phase Pad-Mounted Transformers - GE Grid

    2011-8-15u2002·u2002• Impedance and load losses. • Applied voltage test. • Induced voltage test. • Full-wave impulse test. • Mechanical leak test. Prolec GE offers a complete line of liquid-filled Three-Phase Pad-Mounted distribution transformers that meet applicable ANSI®/IEEE® standards. With high voltages up to 34.5 kV and ratings up to 5,000

    Get Price
  • Single Phase Pad Mounted Distribution Transformer

    2014-3-14u2002·u2002Single Phase Pad Mounted Distribution Transformer ERMCO single phase pad mounted distribution transformers are designed and manufactured in compliance with all applicable IEEE and RUS standards. All transformers are oil filled, 65°C rise, and designed for usual service conditions per IEEE C57.12.00. Types of Single Phase Pad Mounted Transformers

    Get Price
  • Transformers Presentation - University of Ottawa

    2015-3-19u2002·u20023Ø Transformer product scope Pad-mounted and Substation transformers kVA range: 45-12,000 Envirotemp™ FR3™ Filled Primary Voltage 2400 to 46,000 volts Up to 250 kV BIL Secondary Voltage 120 to 24,940 volts 125 kV BIL 59

    Get Price
  • MAXIMUM FAULT CURRENTS FOR PADMOUNTED

    2017-11-10u2002·u2002* If actual transformer impedance is less than 2.2%, fault current values will need to be recalculated. NOTE: THE FAULT CURRENTS LISTED ABOVE ARE MAXIMUM FAULT CURRENT VALUES. IF MORE EXACT VALUES ARE NEEDED FOR ARC FLASH STUDIES, PROTECTION COORDINATION STUDIES, OR OTHER REASONS, PLEASE CONTACT YOUR ACCOUNT …

    Get Price
  • Functional specification for three-phase pad-mounted ...

    2021-9-8u2002·u2002Functional Specification for Three-Phase Pad-Mounted Distribution Transformers 45 – 10,000 kVA 1.0 Scope 1.1. This specification covers the electrical and mechanical characteristics of Eaton's Cooper Power series 45-10,000 kVA Three-Phase Step-Down Pad-Mounted Distribution Transformers. KVA ratings for transformers with secondary voltages not

    Get Price
  • impedance of a 500kVA pad mounted transformer

    2008-5-31u2002·u2002I'm putting in a new switchboard which will be fed via an existing 13.8 to 208Y/120V pad mounted transformer. I don't know how old it is (yes it might be a good idea to take a look) but at this point I'm told by the onsite electrician that there is no indication of it's impedance on inside nameplate.

    Get Price
  • Data Bulletin 7230DB0501R04/16 04/2016 Replaces ...

    2021-8-14u2002·u2002Data Bulletin 7230DB0501R04/16 04/2016 Replaces 7230DB0501R08/10 08/2010 Pad-Mounted, Small Power Transformers 75–20,000 kVA, 2.5–46 kV Primary Voltage, 120 V–25 kV Secondary Voltage

    Get Price
  • Transformer impedance - Electric power & transmission ...

    2010-10-28u2002·u2002Transformer impedances vary in various markets and with different utilities.In many utilities it was evolved based on historical reasons.Initially transformer engineers were not aware of the importance of impedance and went for as low a value as possible to limit regulation.Later when system fault levels went up need for a minimum impedance to limit fault current became evident.In general US ...

    Get Price
  • TRANSFORMER SECONDARY FAULT CURRENTS TABLES

    2017-8-31u2002·u2002Where one transformer is larger than the others in the bank, use the fault current value for the larger transformer. Pad Mounted Transformers Three Phase Padmounts Size (KVA) Impedance (%) Voltage (Ph-Ph) Sym Fault Current (Amps) 75 1.80 208 11,566 150 1.80 208 23,131 300 1.80 208 46,262 500 3.00 208 46,262 750 5.32 208 39,131

    Get Price
  • Classes 7200, 7300, 7400 - Steven Engineering

    2004-10-26u2002·u2002Transformers Table of Contents PAD-MOUNTED Page 5 SUBSTATION Page 13 ... Impedance shall be [_____%] [manufacturer's standard impedance], ±7-1/2%. Basic impulse level of the primary winding shall be [_____kV] [as specified in ANSI C57.12.00 for comparable kV class]. G. The transformer shall be of sealed-tank construction or sufficient ...

    Get Price
  • Transformer cheat sheet - ABB

    2013-12-23u2002·u2002GE Transformer Currents for Substation & Pad Mount Transformers Simple Calculations Detailed Calculations Transformer Tables Go To Simple Calculations Go To Main Sheet Primary Short circuit Amps = X/R1 = Are you assuming Infinite Source? Source Data Transformer Data Source Impedance Calculation (%Z1): X/R2 = 2.0 x rated motor load current at ...

    Get Price
  • PAD-MOUNTED DISTRIBUTION TRANSFORMERS

    2021-3-16u2002·u2002The Power Partners commitment to manufacture quality pad-mounted distribution transformers is backed by a series of transformer tests used to verify conformance to performance characteristics outlined in the latest revisions of ANSI C57.12.00, ANSI C57.12.90 and ANSI C57.12.29.

    Get Price
  • No. K007 ENGINEERING SPECIFICATION CATEGORY:

    2019-12-11u2002·u2002Identically rated transformers shall be suitable for parallel operation and shall be built to industry tolerance for impedance of ±7.5% per IEEE C57.12.00. 5.1.8 When a transformer's impedance is specified in the bid document, it shall be designed to be used in a parallel application, at rated voltage, with a transformer of the same impedance.

    Get Price
  • SUBSTATION - ELECTRICAL EQUIPMENT

    2019-7-26u2002·u2002Pad Mounted Transformers ... Table-A Drawings And Data Schedule .....2.1 - 3 2. Installation Drawings And Data ... Transformer percent impedance voltage ratings shall fall within the following limits: Percent Impedance Voltage Rating Limits .

    Get Price
  • Data Bulletin 7230DB0501R04/16 04/2016 Replaces ...

    2021-8-14u2002·u2002Data Bulletin 7230DB0501R04/16 04/2016 Replaces 7230DB0501R08/10 08/2010 Pad-Mounted, Small Power Transformers 75–20,000 kVA, 2.5–46 kV Primary Voltage, 120 V–25 kV Secondary Voltage

    Get Price
  • IEEE Std C57.12.34-2009, 'IEEE Standard for Requirements ...

    2018-3-4u2002·u2002IEEE Std C57.12.34, 'IEEE Standard for Requirements for Pad-Mounted Transformer' Timothy L. O'Hearn, PE. Course Outline. This 5-hour course covers certain electrical, dimensional, and mechanical characteristics and takes into consideration certain safety features of three-phase, 60 Hz, liquid-filled, self-cooled, pad-mounted, compartment-type distribution transformers.

    Get Price
  • Specification – Distribution Transformers

    ground-mounted distribution transformers for use in its threephase, single phase, and single wire earth wire return (SWEWR) electricity distribution systems.

    Get Price
  • Pole top transformer impedance

    2019-6-26u2002·u2002Consider a 1 to 1 transformer with the secondary center tapped with tight coupling primary to secondary. Consider the internal series impedances to be Zpri = Zsec and 1/2 of secondary being Zsec/2 or Zpri/2. For a short on the whole secondary the equivalent impedance at the primary equals 2*Zpri. For a short on only 1/2 of the secondary the ...

    Get Price
  • Three-Phase Pad-Mounted Transformers - GE Grid Solutions

    2011-8-15u2002·u2002• Impedance and load losses. • Applied voltage test. • Induced voltage test. • Full-wave impulse test. • Mechanical leak test. Prolec GE offers a complete line of liquid-filled Three-Phase Pad-Mounted distribution transformers that meet applicable ANSI®/IEEE® standards. With high voltages up to 34.5 kV and ratings up to 5,000

    Get Price
  • Single Phase Pad Mounted Distribution Transformer

    2014-3-14u2002·u2002Single Phase Pad Mounted Distribution Transformer ERMCO single phase pad mounted distribution transformers are designed and manufactured in compliance with all applicable IEEE and RUS standards. All transformers are oil filled, 65°C rise, and designed for usual service conditions per IEEE C57.12.00. Types of Single Phase Pad Mounted Transformers

    Get Price
  • Three Phase Padmounted and Unit Substation Transformers

    2013-12-30u2002·u2002Each transformer manufactured by ABB must undergo a series of tests. 1. Polarity, Phase-Relation, and Ratio 2. Demag Test 3. Applied Voltage Test of the HV 4. Applied Voltage Test of the LV 5. Induced Voltage Test 6. No-Load (Excitation) Loss and Excitation Current 7. Impedance Voltage and Load Loss 8. Full Wave Impulse 9. Continuity Check Test ...

    Get Price
  • Transformer solutions across the grid

    2018-2-11u2002·u2002Pad-Mounted Transformers Prolec GE manufactures a complete line of single-phase pad-mounted distribution transformers designed to provide the features, performance and aesthetics needed for modern underground residential applications. We utilize state-of-the-art technology in our design and manufacturing systems, supported by our ISO-9001

    Get Price
  • MAXIMUM FAULT CURRENTS FOR PADMOUNTED

    2017-11-10u2002·u2002* If actual transformer impedance is less than 2.2%, fault current values will need to be recalculated. NOTE: THE FAULT CURRENTS LISTED ABOVE ARE MAXIMUM FAULT CURRENT VALUES. IF MORE EXACT VALUES ARE NEEDED FOR ARC FLASH STUDIES, PROTECTION COORDINATION STUDIES, OR OTHER REASONS, PLEASE CONTACT YOUR ACCOUNT …

    Get Price
  • SUBSTATION - ELECTRICAL EQUIPMENT SPECIFICATIONS

    2019-7-26u2002·u2002Pad Mounted Transformers ... Table-A Drawings And Data Schedule .....2.1 - 3 2. Installation Drawings And Data ... Transformer percent impedance voltage ratings shall fall within the following limits: Percent Impedance Voltage Rating Limits .

    Get Price
  • CITY OF DOVER ELECTRIC DEPARTMENT SPECIFYING

    cooled, pad-mounted, compartmental-type distributions transformers shall be in accordance with IEEE C57.12.34, Table 3 and Table 4, and have the following ratings: 75 through 3000kVA 65° C average winding rise or 80° C hot spot temperature rise 60 hertz HV: 12470GRDY/7200 HV BIL: 95kV LV: 208Y/120, 480Y/277, 240/120

    Get Price
  • ENERGY DELIVERY ENGINEERING SPECIFICATION EDEN-212

    2017-5-9u2002·u2002a. Percent impedance at 85 degrees C b. Percent excitation current c. Excitation loss at 85 degrees C and 100% rated voltage expressed in watts d. Load loss at 85 degrees C and rated load expressed in watts 6. CONSTRUCTION 6.1. The pad-mounted transformers shall meet the requirements for tamper resistance as

    Get Price
  • pad mounted transformer impedance - Electric power ...

    2010-3-21u2002·u2002I donot know from which ANSI standard you have sid that a 300 kVA pad mounted transformer shall have only 4% impedance.In fact the relevant IEEE std is IEEE C57.12.26 which specifies the impedance can be between 1.2-6.0.Therefore, if your short circuit results are ok with 4.42% then there cannot be a problem.

    Get Price
  • Typical Transformer %Z Values

    2009-11-5u2002·u2002However, inductance is the predominant impedance in a transformer, so the configuration and size of the core and coil assembly will impact the %Z. When looking only at KVA ratings, liquid filled transformers usually have relatively smaller and more compact windings and therefore lower %Z than do dry type units. M.

    Get Price
  • Three-Phase Pad-Mounted Transformers - GE Grid

    2011-8-15u2002·u2002• Impedance and load losses. • Applied voltage test. • Induced voltage test. • Full-wave impulse test. • Mechanical leak test. Prolec GE offers a complete line of liquid-filled Three-Phase Pad-Mounted distribution transformers that meet applicable ANSI®/IEEE® standards. With high voltages up to 34.5 kV and ratings up to 5,000

    Get Price
  • CITY OF DOVER ELECTRIC DEPARTMENT SPECIFYING

    cooled, pad-mounted, compartmental-type distributions transformers shall be in accordance with IEEE C57.12.34, Table 3 and Table 4, and have the following ratings: 75 through 3000kVA 65° C average winding rise or 80° C hot spot temperature rise 60 hertz HV: 12470GRDY/7200 HV BIL: 95kV LV: 208Y/120, 480Y/277, 240/120

    Get Price
  • SUBSTATION - ELECTRICAL EQUIPMENT

    2019-7-26u2002·u2002Pad Mounted Transformers ... Table-A Drawings And Data Schedule .....2.1 - 3 2. Installation Drawings And Data ... Transformer percent impedance voltage ratings shall fall within the following limits: Percent Impedance Voltage Rating Limits .

    Get Price
  • No. K007 ENGINEERING SPECIFICATION CATEGORY:

    2019-12-11u2002·u2002Identically rated transformers shall be suitable for parallel operation and shall be built to industry tolerance for impedance of ±7.5% per IEEE C57.12.00. 5.1.8 When a transformer's impedance is specified in the bid document, it shall be designed to be used in a parallel application, at rated voltage, with a transformer of the same impedance.

    Get Price
  • 36.01 PAD-MOUNTED EQUIPMENT CLEARANCES 36.02

    2016-4-27u2002·u20020 table of contents 2 1 revised by ck'd appr. 3 pad-mounted transformer clearances from buildings 36.01 pad-mounted equipment clearances 36.00-00a dep def x dec dem 36.01-101 pad-mounted equipment working space and miscellaneous clearances 36.01-103 protective poles for pad-mounted equipment 36.01-105 underground clearances from other utilities ...

    Get Price
  • MAXIMUM FAULT CURRENTS FOR PADMOUNTED

    2017-11-10u2002·u2002* If actual transformer impedance is less than 2.2%, fault current values will need to be recalculated. NOTE: THE FAULT CURRENTS LISTED ABOVE ARE MAXIMUM FAULT CURRENT VALUES. IF MORE EXACT VALUES ARE NEEDED FOR ARC FLASH STUDIES, PROTECTION COORDINATION STUDIES, OR OTHER REASONS, PLEASE CONTACT YOUR ACCOUNT …

    Get Price
  • Equivalencing the Collector Conference Paper

    2013-9-26u2002·u2002the pad-mounted transformer is considered to be part of the generator itself. At this stage, we are only interested in the equivalent impedance of the collector system, excluding the pad-mounted transformers. Each of the currents shown is a phasor quantity, as follows: I. m = I. m θ. m. In this paper, a boldfaced variable indicates a phasor ...

    Get Price
  • Table 8-1. Transformer Standard Base kVA Ratings.

    with the standard sizes listed in table 8-1. Pad-. lorobenzene (TCB) will not be used as an insulat-. mounted compartmental units are not available. ing fluid since it is a possible carcinnogen. TCB. for ratings of less than 25 kVA for single-phase. may be used as a cleaning agent during the. units or 75 kVA for three-phase units.

    Get Price
  • Typical Transformer %Z Values

    2009-11-5u2002·u2002However, inductance is the predominant impedance in a transformer, so the configuration and size of the core and coil assembly will impact the %Z. When looking only at KVA ratings, liquid filled transformers usually have relatively smaller and more compact windings and therefore lower %Z than do dry type units. M.

    Get Price
  • Selection of fuses for the protection of transformers

    2021-8-14u2002·u2002the transformer, is always greater than the transformer inrush current. Imin.fuse blow> X x Irt - X and T are coming from the transformer supplier's characteristics table. - If the transient characteristics of the transformer are unknown, an empirical rule may be used. This consists in checking that the fuse-blowing current at

    Get Price
  • PAD-MOUNTED DISTRIBUTION TRANSFORMERS

    2021-3-16u2002·u2002The Power Partners commitment to manufacture quality pad-mounted distribution transformers is backed by a series of transformer tests used to verify conformance to performance characteristics outlined in the latest revisions of ANSI C57.12.00, ANSI C57.12.90 and …

    Get Price
  • DSTAR - Transformer Impedance Considerations

    The impedance of three-phase pad-mounted transformers is governed primarily by the ANSI Standard C57.;12.26 that specifies an impedance of 5.75% for transformers of size 750-2500 kVA. Application of any standard is wholly voluntary, unless adopted by a governmental body, but some manufacturers are reluctant to offer lower impedance designs and ...

    Get Price
  • Equivalencing the Collector Conference Paper

    2013-9-26u2002·u2002the pad-mounted transformer is considered to be part of the generator itself. At this stage, we are only interested in the equivalent impedance of the collector system, excluding the pad-mounted transformers. Each of the currents shown is a phasor quantity, as follows: I. m = I. m θ. m. In this paper, a boldfaced variable indicates a phasor ...

    Get Price
  • SUBSTATION - ELECTRICAL EQUIPMENT SPECIFICATIONS

    2019-7-26u2002·u2002Pad Mounted Transformers ... Table-A Drawings And Data Schedule .....2.1 - 3 2. Installation Drawings And Data ... Transformer percent impedance voltage ratings shall fall within the following limits: Percent Impedance Voltage Rating Limits .

    Get Price
  • 36.01 PAD-MOUNTED EQUIPMENT CLEARANCES 36.02

    2016-4-27u2002·u20020 table of contents 2 1 revised by ck'd appr. 3 pad-mounted transformer clearances from buildings 36.01 pad-mounted equipment clearances 36.00-00a dep def x dec dem 36.01-101 pad-mounted equipment working space and miscellaneous clearances 36.01-103 protective poles for pad-mounted equipment 36.01-105 underground clearances from other utilities ...

    Get Price
  • LOW PROFILE, SINGLE PHASE, PAD-MOUNTED

    2020-12-18u2002·u2002Low-profile, single phase, pad-mounted distribution transformers with separable insulated high-voltage connectors Hydro Ottawa UTS0006 Transformer Signage 1 Phase Padmount - Identification Detail Hydro Ottawa EMS0001 Transformer Financial Operating Loss Formula IEEE C57.12.35 IEEE Standard for Bar Coding for Distribution

    Get Price
  • VA 26 12 19 Pad-Mounted, Liquid-Filled, Medium-Voltage ...

    2018-1-17u2002·u2002PAD-MOUNTED, LIQUID-FILLED, MEDIUM-VOLTAGE TRANSFORMERS . SPEC WRITER NOTE: Delete between //----/ if not applicable to project. This spec is applicable for transformers 2500 kVA and less, on 5 kV and 15 kV primary systems, with source not over 8.3 kV phase to ground. Any system higher than 15kV and 35kV or less is only allowed with VA approval.

    Get Price
  • IEEE C57.12.34-2015 - IEEE Standard Requirements for Pad ...

    2021-9-16u2002·u2002Certain electrical, dimensional, and mechanical characteristics are set forth as well as certain safety features of three-phase, 60 Hz, liquid-immersed, self-cooled, pad-mounted, compartmental-type distribution transformers. These transformers are rated 10 MVA and smaller, with the high-voltage limit of 34.5 kV nominal system voltage and below, and with low-voltage …

    Get Price
  • ABB Liquid Pad Mount 1,500 KVA Transformer

    Transformer Remanufacturing. RESA Power re-manufactured transformers provide the same performance as a new transformer at a much lower cost. The RESA Power Transformer Re-manufacturing Service offers a new lease on life for this used ABB Liquid Pad Mount 1,500 KVA Transformer, enabling it to be completely rebuilt and returned to good-as-new condition, or even …

    Get Price
  • What is the percent impedance of a typical residential ...

    2021-8-4u2002·u2002I have seen 2,500 kVA transformers ordered with impedance of 12%, which is double the minimum standard impedance, for fault limiting purposes. It is not common to ask for a transformer with less than the standard impedance, as such a transformer will have a very high LV fault level, which is bad for equipment and personnel safety. Additionally ...

    Get Price