Contact Us

Home > Products

15kva single phase dry type transformer 480v primary

Just fill in the form below, click submit, you will get the price list, and we will contact you within one working day. Please also feel free to contact us via email or phone. (* is required).

  • Eaton - S20L11S15N, Dry Type - 15 KVA, Transformers,

    Eaton S20L11S15N Transformer, 15KVA, 1P, 240/480V, 120/240V, Encapsulated 15 KVA, 1-Phase, 240 x 480 Primary Volts - 120/240 Secondary Volts, NEMA 3R, General Purpose Transformer, Sand and Resin Encapsulated, 115 Degree C, Aluminum Windings, 60 Hz operation (50/60 Hz optional), Frame Size: FR180. ***Reverse Feed Capable and for use with 3-Phase Source by connecting primary to any two …

    Get Price
  • Eaton S20L11S15N :: Transformer, 15KVA, 1P, 240/480V,

    15 KVA, 1-Phase, 240 x 480 Primary Volts - 120/240 Secondary Volts, NEMA 3R, General Purpose Transformer, Sand and Resin Encapsulated, 115 Degree C, Aluminum Windings, 60 Hz operation (50/60 Hz optional), Frame Size: FR180. ***Reverse Feed Capable and for use with 3-Phase Source by connecting primary to any two wires of a 3-Phase System***, Cat #: S20L11S15N, Mfr: Eaton

    Get Price
  • Eaton - V48M28T1516, Dry Type - 15 KVA, Transformers ...

    Eaton V48M28T1516 Transformer, Dry Type, TP-1, 480 x 120/208V, 3PH, 15 kVA, 15 KVA, 3-Phase, 480 Delta Primary Volts - 208Y/120 Secondary Volts, NEMA 1, Energy Efficient, Energy Star labeled Transformer, Ventilated, 150 Degree C, Aluminum Windings, 60 Hz operation, Frame Size: FR939. For Outdoor use Weather Shield WS57. DOE 2016 Efficient.

    Get Price
  • 15 KVA Transformer Primary 240 x 480 Secondary 120/240 ...

    FEDERAL PACIFIC, Dry Type Transformer, Stock No. 11-9629, 1 Phase, KVA 15, Primary Voltage 240 x 480, Secondary Voltage 120/240, No Taps Taps, 115 ºC Temp Rating, Impedance Pct., 270 Lbs. Weight, 17.00 Inches Height, 13.12 Inches Depth, Catalog Number P2XLF21-15-N, New Price $880.00

    Get Price
  • Eaton - V48M22T1516, Dry Type - 15 KVA, Transformers ...

    Eaton V48M22T1516 15KVA, 3P, 480V, 240V, Energy Efficient Transformer 15 KVA, 3-Phase, 480 Delta Primary Volts - 240 Delta Secondary Volts with 120 Volt Lighting Tap, NEMA 1, Energy Efficient, Energy Star labeled Transformer, Ventilated, 150 Degree C, Aluminum Windings, 60 Hz operation, Frame Size: FR939. For Outdoors use Weather Shield WS57.

    Get Price
  • Square D (Schneider Electric) EE15S3H Dry-Type

    Shop Dry-Type Transformer, Energy Efficient, 1-Phase, 15 KVA, 240 X 480 Primary, 120/240V Secondary, NEMA 1 By Square D (Schneider Electric) (EE15S3H) At Graybar, Your Trusted Resource For Dry-Type Transformers And Other Square D (Schneider Electric) Products.

    Get Price
  • Dry Type Transformers - Siemens

    2021-9-13u2002·u2002DRY TYPE TRANSFORMERS NRCAN Rated General Purpose Transformers Industrial Type Copper Winding Selection a W = Wall mount F = Floor mount b Taps: Single phase: 15-250 kVA - 2 x FCAN, 2 x FCBN Three phase: 15-300 kVA - 2 x FCAN, 2 x FCBN All weights and dimensions are approximate and subject to change without notice.

    Get Price
  • Dry Type Transformers Full Line Catalog - Jefferson Electric

    2021-3-16u2002·u2002Single-Phase Ventilated 1-3 Single-Phase General Purpose Transformers – DOE Compliant 150°C Temperature Rise • Aluminum Windings • NEMA3R Enclosures Taps: 2 @ 2.5% FCAN & 4 @ 2.5% FCBN 240 x 480V — 120/240V kVA Catalog Number Enclosure Figure Height (A) inches Width (B) inches Depth (C) inches (D) inches (E) inches Est Ship Wgt Wiring ...

    Get Price
  • 15kva XFMR Calculation

    2007-8-3u2002·u2002I wanted to figure the size of a primary breaker for a 15kva transformer: 480v single phase primary to 120/240v single phase secondary, 15000 divided by 480 = 31.25 amps. Is this correct? The load draw would be around 55 amps, would a 30amp primary breaker be sufficiant for this transformer?

    Get Price
  • Sizing Guide for Dry Type Transformers - LynTec

    2010-12-10u2002·u2002Sizing Guide for Dry Type Transformers Single Phase Transformers Primary Voltage Main Breaker kVA Rating Primary Lugs Secondary Lugs 208V 80A 15 100A 100A 208V 150A 25 250A 250A 208V 200A 37.5 250A 250A 208V 225A 50 400A 400A 240V 80A 15 100A 100A 240V 150A 25 250A 250A 240V 200A 37.5 250A 250A 240V 225A 50 400A 400A Three Phase Transformers ...

    Get Price
  • Eaton - S20L11S15N, Dry Type - 15 KVA, Transformers,

    Eaton S20L11S15N Transformer, 15KVA, 1P, 240/480V, 120/240V, Encapsulated 15 KVA, 1-Phase, 240 x 480 Primary Volts - 120/240 Secondary Volts, NEMA 3R, General Purpose Transformer, Sand and Resin Encapsulated, 115 Degree C, Aluminum Windings, 60 Hz operation (50/60 Hz optional), Frame Size: FR180. ***Reverse Feed Capable and for use with 3-Phase Source by connecting primary to any two …

    Get Price
  • Eaton S20L11S15N :: Transformer, 15KVA, 1P, 240/480V,

    15 KVA, 1-Phase, 240 x 480 Primary Volts - 120/240 Secondary Volts, NEMA 3R, General Purpose Transformer, Sand and Resin Encapsulated, 115 Degree C, Aluminum Windings, 60 Hz operation (50/60 Hz optional), Frame Size: FR180. ***Reverse Feed Capable and for use with 3-Phase Source by connecting primary to any two wires of a 3-Phase System***, Cat #: S20L11S15N, Mfr: Eaton

    Get Price
  • Eaton - V48M28T1516, Dry Type - 15 KVA, Transformers ...

    Eaton V48M28T1516 Transformer, Dry Type, TP-1, 480 x 120/208V, 3PH, 15 kVA, 15 KVA, 3-Phase, 480 Delta Primary Volts - 208Y/120 Secondary Volts, NEMA 1, Energy Efficient, Energy Star labeled Transformer, Ventilated, 150 Degree C, Aluminum Windings, 60 Hz operation, Frame Size: FR939. For Outdoor use Weather Shield WS57. DOE 2016 Efficient.

    Get Price
  • 15 KVA Transformer Primary 240 x 480 Secondary 120/240 ...

    FEDERAL PACIFIC, Dry Type Transformer, Stock No. 11-9629, 1 Phase, KVA 15, Primary Voltage 240 x 480, Secondary Voltage 120/240, No Taps Taps, 115 ºC Temp Rating, Impedance Pct., 270 Lbs. Weight, 17.00 Inches Height, 13.12 Inches Depth, Catalog Number P2XLF21-15-N, New Price $880.00

    Get Price
  • Eaton - V48M22T1516, Dry Type - 15 KVA, Transformers ...

    Eaton V48M22T1516 15KVA, 3P, 480V, 240V, Energy Efficient Transformer 15 KVA, 3-Phase, 480 Delta Primary Volts - 240 Delta Secondary Volts with 120 Volt Lighting Tap, NEMA 1, Energy Efficient, Energy Star labeled Transformer, Ventilated, 150 Degree C, Aluminum Windings, 60 Hz operation, Frame Size: FR939. For Outdoors use Weather Shield WS57.

    Get Price
  • Square D (Schneider Electric) EE15S3H Dry-Type

    Shop Dry-Type Transformer, Energy Efficient, 1-Phase, 15 KVA, 240 X 480 Primary, 120/240V Secondary, NEMA 1 By Square D (Schneider Electric) (EE15S3H) At Graybar, Your Trusted Resource For Dry-Type Transformers And Other Square D (Schneider Electric) Products.

    Get Price
  • Dry Type Transformers - Siemens

    2021-9-13u2002·u2002DRY TYPE TRANSFORMERS NRCAN Rated General Purpose Transformers Industrial Type Copper Winding Selection a W = Wall mount F = Floor mount b Taps: Single phase: 15-250 kVA - 2 x FCAN, 2 x FCBN Three phase: 15-300 kVA - 2 x FCAN, 2 x FCBN All weights and dimensions are approximate and subject to change without notice.

    Get Price
  • Dry Type Transformers Full Line Catalog - Jefferson Electric

    2021-3-16u2002·u2002Single-Phase Ventilated 1-3 Single-Phase General Purpose Transformers – DOE Compliant 150°C Temperature Rise • Aluminum Windings • NEMA3R Enclosures Taps: 2 @ 2.5% FCAN & 4 @ 2.5% FCBN 240 x 480V — 120/240V kVA Catalog Number Enclosure Figure Height (A) inches Width (B) inches Depth (C) inches (D) inches (E) inches Est Ship Wgt Wiring ...

    Get Price
  • 15kva XFMR Calculation

    2007-8-3u2002·u2002I wanted to figure the size of a primary breaker for a 15kva transformer: 480v single phase primary to 120/240v single phase secondary, 15000 divided by 480 = 31.25 amps. Is this correct? The load draw would be around 55 amps, would a 30amp primary breaker be sufficiant for this transformer?

    Get Price
  • Sizing Guide for Dry Type Transformers - LynTec

    2010-12-10u2002·u2002Sizing Guide for Dry Type Transformers Single Phase Transformers Primary Voltage Main Breaker kVA Rating Primary Lugs Secondary Lugs 208V 80A 15 100A 100A 208V 150A 25 250A 250A 208V 200A 37.5 250A 250A 208V 225A 50 400A 400A 240V 80A 15 100A 100A 240V 150A 25 250A 250A 240V 200A 37.5 250A 250A 240V 225A 50 400A 400A Three Phase Transformers ...

    Get Price
  • 15kva Single Phase Transformer

    15 KVA Transformer Primary 240 x 480 Secondary 120/240 ... › Best Education From www.swgr.com Education Details: FEDERAL PACIFIC, Dry Type Transformer, Stock No. 11-9629, 1 Phase, KVA 15, Primary Voltage 240 x 480, Secondary Voltage 120/240, No Taps Taps, 115 ºC Temp Rating, Impedance Pct., 270 Lbs. Weight, 17.00 Inches Height, 13.12 Inches Depth, Catalog Number P2XLF21-15-N, New …

    Get Price
  • 30 Years of Innovative Solutions for Construction &

    2021-2-12u2002·u2002Cat. No. Transformer Primary Disconnect Secondary Main Breaker Panel No. 6210PDC15-1 15KVA Single Phase 480V 3R Dry-type Transformer 15KVA 30A 125amp 6210 6210PDC15-1E 15KVA Single Phase 480V 4X Encapsulated Transformer 15KVA 30A 125amp 6210 6210PDC25-1 25KVA Single Phase 480V 3R Dry-type Transformer 25KVA 60A 200amp 6210 6210PDC25-1E 25KVA ...

    Get Price
  • Power Product Catalogue - Siemens

    2021-9-10u2002·u2002DRY TYPE TRANSFORMERS POWER PRODUCT Dry Type Transformers Contents ... Single Phase Transformer Amperage Ratings Three Phase Transformer Amperage Ratings. kVA (1 phase) = volts X amps kVA (3 phases) = 1,732 X volts X amps ... * Primary Voltage – F = 480V, G = 600V. See page 7-3 for Catalogue Code Detail. T1*10015C5RXXM. 15. W/F 4 X 2.5 2 24 ...

    Get Price
  • DAYTON 15 kVA Three Phase Transformer, Input Voltage:

    15 kVA Three Phase Transformer, Input Voltage: 480V AC Delta. Item # 44YV01. Mfr. Model # 44YV01. UNSPSC # 39121002. Catalog Page # 208 208. Country of Origin Mexico. Country of Origin is subject to change. Tap image to zoom. Roll over image to zoom.

    Get Price
  • Dry Type Distribution Transformers - Emerson Electric

    2019-2-18u2002·u2002Dry-type transformers, 600 Volt Class, isolation type, single and three phase. Indoor and outdoor models available. Hazardous Location (Encapsulated) Comply with Article 500 of the NEC for Class I, Division 2, A,B,CandDlocations. Buck-Boost Used for outdoor or designer low voltage lighting. When connected properly, these transformers can be ...

    Get Price
  • TEMCo European Voltage Transformers Selection Guide

    Euro Plus Transformers 208V, 240V, 456V, 480V, 504V Delta Primary x 380V, 400V, or 415V Wye Secondary. Usually in stock. To confirm stock status, check the individual product page. 3 Phase, 60 Hz, Dry Type NEMA 3R (rated for outdoor use). Dry type distribution transformer, enclosed ventilated.

    Get Price
  • Transformers - Single Phase Transformer

    square d 480v. 60hz, single phase, dry type, transformer 1.5s1f search square d transformer used condition catalog number: 1.5s1f type s dry type single-phase 480v.60hz item shown is a representative unit. condition will be very similar. please see enlarged photos for additional information.

    Get Price
  • Sizing Guide for Dry Type Transformers - LynTec

    2010-12-10u2002·u2002Sizing Guide for Dry Type Transformers Single Phase Transformers Primary Voltage Main Breaker kVA Rating Primary Lugs Secondary Lugs 208V 80A 15 100A 100A 208V 150A 25 250A 250A 208V 200A 37.5 250A 250A 208V 225A 50 400A 400A 240V 80A 15 100A 100A 240V 150A 25 250A 250A 240V 200A 37.5 250A 250A 240V 225A 50 400A 400A Three Phase Transformers ...

    Get Price
  • Dry Type Transformers Section 10 - ABB

    2019-4-18u2002·u2002Dry Type Transformers General Information Section 10 Types QB, QMS, QL 600 Volts and Below General Information The complete family of transformers from GE provide quiet, reliable transformer operation. All of the dry-type transformers through 1,000 kVA are UL listed under the requirements of Standard 5085 and 1561. In addition,

    Get Price
  • 600V Dry-Type Transformer Manual

    2019-10-8u2002·u2002INDOOR OUTDOOR VENTILATED DRY-TYPE TRANSFORMERS 15-750 KVA. 2 Safety Precautions a) Fully inspect the transformer before unloading and unpacking. ... line current rating of the transformers primary and secondary windings. Cables should be rated for at least 90°C (194°F). ... Any three phase or single phase load may be connected to the ...

    Get Price
  • 15kva Single Phase Transformer

    15 KVA Transformer Primary 240 x 480 Secondary 120/240 ... › Best Education From www.swgr.com Education Details: FEDERAL PACIFIC, Dry Type Transformer, Stock No. 11-9629, 1 Phase, KVA 15, Primary Voltage 240 x 480, Secondary Voltage 120/240, No Taps Taps, 115 ºC Temp Rating, Impedance Pct., 270 Lbs. Weight, 17.00 Inches Height, 13.12 Inches Depth, Catalog Number P2XLF21-15-N, New …

    Get Price
  • 15kva 480 120 240 Transformer - studyeducation.org

    Eaton S20L11S15N Transformer, 15KVA, 1P, 240/480V, 120 ... › Best education the day at www.platt.com Education Details: Eaton S20L11S15N Transformer, 15KVA, 1P, 240/480V, 120/240V, Encapsulated 15 KVA, 1-Phase, 240 x 480 Primary Volts - 120/240 Secondary Volts, NEMA 3R, General Purpose Transformer, Sand and Resin Encapsulated, 115 Degree C, Aluminum Windings, 60 Hz operation …

    Get Price
  • 30 Years of Innovative Solutions for Construction &

    2021-2-12u2002·u2002Cat. No. Transformer Primary Disconnect Secondary Main Breaker Panel No. 6210PDC15-1 15KVA Single Phase 480V 3R Dry-type Transformer 15KVA 30A 125amp 6210 6210PDC15-1E 15KVA Single Phase 480V 4X Encapsulated Transformer 15KVA 30A 125amp 6210 6210PDC25-1 25KVA Single Phase 480V 3R Dry-type Transformer 25KVA 60A 200amp 6210 6210PDC25-1E 25KVA ...

    Get Price
  • Power Product Catalogue - Siemens

    2021-9-10u2002·u2002DRY TYPE TRANSFORMERS POWER PRODUCT Dry Type Transformers Contents ... Single Phase Transformer Amperage Ratings Three Phase Transformer Amperage Ratings. kVA (1 phase) = volts X amps kVA (3 phases) = 1,732 X volts X amps ... * Primary Voltage – F = 480V, G = 600V. See page 7-3 for Catalogue Code Detail. T1*10015C5RXXM. 15. W/F 4 X 2.5 2 24 ...

    Get Price
  • DAYTON 15 kVA Three Phase Transformer, Input Voltage:

    15 kVA Three Phase Transformer, Input Voltage: 480V AC Delta. Item # 44YV01. Mfr. Model # 44YV01. UNSPSC # 39121002. Catalog Page # 208 208. Country of Origin Mexico. Country of Origin is subject to change. Tap image to zoom. Roll over image to zoom.

    Get Price
  • Dry Type Transformers Section 10 - ABB

    2019-4-18u2002·u2002Dry Type Transformers General Information Section 10 Types QB, QMS, QL 600 Volts and Below General Information The complete family of transformers from GE provide quiet, reliable transformer operation. All of the dry-type transformers through 1,000 kVA are UL listed under the requirements of Standard 5085 and 1561. In addition,

    Get Price
  • Transformers - Single Phase Transformer

    square d 480v. 60hz, single phase, dry type, transformer 1.5s1f search square d transformer used condition catalog number: 1.5s1f type s dry type single-phase 480v.60hz item shown is a representative unit. condition will be very similar. please see enlarged photos for additional information.

    Get Price
  • TEMCo European Voltage Transformers Selection Guide

    Euro Plus Transformers 208V, 240V, 456V, 480V, 504V Delta Primary x 380V, 400V, or 415V Wye Secondary. Usually in stock. To confirm stock status, check the individual product page. 3 Phase, 60 Hz, Dry Type NEMA 3R (rated for outdoor use). Dry type distribution transformer, enclosed ventilated.

    Get Price
  • Single-phase distribution transformers up to 315 kVA

    2021-9-7u2002·u2002Range up to 315 kVA. Hitachi ABB Power Grids liquid-filled, single-phase pole or pad mounted distribution transformers are specifically designed for networks where it is not practical to have a three-phase supply. They are typically used for servicing residential overhead distribution loads.

    Get Price
  • 3-Phase 480V Delta - 240V Delta 120 – Maddox Industrial ...

    This transformer is designed to convert 3-phase 480v to 3-phase 240v to run equipment such as panels, motors, CNC machines, welders, conveyor systems, pumps, printing equipment, fabrication tools, cryptocurrency miners, datacenter equipment, and other business machines.. Primary Voltage: 480 Delta Secondary Voltage: 240 Delta 120. This model comes with a center tap (AKA lighting tap) to run ...

    Get Price
  • Eaton - S20L11S15N, Dry Type - 15 KVA, Transformers,

    Eaton S20L11S15N Transformer, 15KVA, 1P, 240/480V, 120/240V, Encapsulated 15 KVA, 1-Phase, 240 x 480 Primary Volts - 120/240 Secondary Volts, NEMA 3R, General Purpose Transformer, Sand and Resin Encapsulated, 115 Degree C, Aluminum Windings, 60 Hz operation (50/60 Hz optional), Frame Size: FR180. ***Reverse Feed Capable and for use with 3-Phase Source by connecting primary to …

    Get Price
  • Eaton S20L11S15N :: Transformer, 15KVA, 1P, 240/480V,

    15 KVA, 1-Phase, 240 x 480 Primary Volts - 120/240 Secondary Volts, NEMA 3R, General Purpose Transformer, Sand and Resin Encapsulated, 115 Degree C, Aluminum Windings, 60 Hz operation (50/60 Hz optional), Frame Size: FR180. ***Reverse Feed Capable and for use with 3-Phase Source by connecting primary to any two wires of a 3-Phase System***, Cat #: S20L11S15N, Mfr: Eaton

    Get Price
  • Eaton - V48M28T1516, Dry Type - 15 KVA, Transformers ...

    Eaton V48M28T1516 Transformer, Dry Type, TP-1, 480 x 120/208V, 3PH, 15 kVA, 15 KVA, 3-Phase, 480 Delta Primary Volts - 208Y/120 Secondary Volts, NEMA 1, Energy Efficient, Energy Star labeled Transformer, Ventilated, 150 Degree C, Aluminum Windings, 60 Hz operation, Frame Size: FR939. For Outdoor use Weather Shield WS57. DOE 2016 Efficient.

    Get Price
  • 15 KVA Transformer Primary 240 x 480 Secondary 120/240 ...

    FEDERAL PACIFIC, Dry Type Transformer, Stock No. 11-9629, 1 Phase, KVA 15, Primary Voltage 240 x 480, Secondary Voltage 120/240, No Taps Taps, 115 ºC Temp Rating, Impedance Pct., 270 Lbs. Weight, 17.00 Inches Height, 13.12 Inches Depth, Catalog Number P2XLF21-15-N, New Price $880.00

    Get Price
  • Eaton - V48M22T1516, Dry Type - 15 KVA, Transformers ...

    Eaton V48M22T1516 15KVA, 3P, 480V, 240V, Energy Efficient Transformer 15 KVA, 3-Phase, 480 Delta Primary Volts - 240 Delta Secondary Volts with 120 Volt Lighting Tap, NEMA 1, Energy Efficient, Energy Star labeled Transformer, Ventilated, 150 Degree C, Aluminum Windings, 60 Hz operation, Frame Size: FR939. For Outdoors use Weather Shield WS57.

    Get Price
  • Square D (Schneider Electric) EE15S3H Dry-Type

    Shop Dry-Type Transformer, Energy Efficient, 1-Phase, 15 KVA, 240 X 480 Primary, 120/240V Secondary, NEMA 1 By Square D (Schneider Electric) (EE15S3H) At Graybar, Your Trusted Resource For Dry-Type Transformers And Other Square D (Schneider Electric) Products.

    Get Price
  • Dry Type Transformers - Siemens

    2021-9-13u2002·u2002DRY TYPE TRANSFORMERS NRCAN Rated General Purpose Transformers Industrial Type Copper Winding Selection a W = Wall mount F = Floor mount b Taps: Single phase: 15-250 kVA - 2 x FCAN, 2 x FCBN Three phase: 15-300 kVA - 2 x FCAN, 2 x FCBN All weights and dimensions are approximate and subject to change without notice.

    Get Price
  • Dry Type Transformers Full Line Catalog - Jefferson Electric

    2021-3-16u2002·u2002Single-Phase Ventilated 1-3 Single-Phase General Purpose Transformers – DOE Compliant 150°C Temperature Rise • Aluminum Windings • NEMA3R Enclosures Taps: 2 @ 2.5% FCAN & 4 @ 2.5% FCBN 240 x 480V — 120/240V kVA Catalog Number Enclosure Figure Height (A) inches Width (B) inches Depth (C) inches (D) inches (E) inches Est Ship Wgt Wiring ...

    Get Price
  • 15kva XFMR Calculation

    2007-8-3u2002·u2002I wanted to figure the size of a primary breaker for a 15kva transformer: 480v single phase primary to 120/240v single phase secondary, 15000 divided by 480 = 31.25 amps. Is this correct? The load draw would be around 55 amps, would a 30amp primary breaker be sufficiant for this transformer?

    Get Price
  • Sizing Guide for Dry Type Transformers - LynTec

    2010-12-10u2002·u2002Sizing Guide for Dry Type Transformers Single Phase Transformers Primary Voltage Main Breaker kVA Rating Primary Lugs Secondary Lugs 208V 80A 15 100A 100A 208V 150A 25 250A 250A 208V 200A 37.5 250A 250A 208V 225A 50 400A 400A 240V 80A 15 100A 100A 240V 150A 25 250A 250A 240V 200A 37.5 250A 250A 240V 225A 50 400A 400A Three Phase Transformers ...

    Get Price
  • Eaton - S20L11S15N, Dry Type - 15 KVA, Transformers,

    Eaton S20L11S15N Transformer, 15KVA, 1P, 240/480V, 120/240V, Encapsulated 15 KVA, 1-Phase, 240 x 480 Primary Volts - 120/240 Secondary Volts, NEMA 3R, General Purpose Transformer, Sand and Resin Encapsulated, 115 Degree C, Aluminum Windings, 60 Hz operation (50/60 Hz optional), Frame Size: FR180. ***Reverse Feed Capable and for use with 3-Phase Source by connecting primary to …

    Get Price
  • Eaton S20L11S15N :: Transformer, 15KVA, 1P, 240/480V,

    15 KVA, 1-Phase, 240 x 480 Primary Volts - 120/240 Secondary Volts, NEMA 3R, General Purpose Transformer, Sand and Resin Encapsulated, 115 Degree C, Aluminum Windings, 60 Hz operation (50/60 Hz optional), Frame Size: FR180. ***Reverse Feed Capable and for use with 3-Phase Source by connecting primary to any two wires of a 3-Phase System***, Cat #: S20L11S15N, Mfr: Eaton

    Get Price
  • Eaton - V48M28T1516, Dry Type - 15 KVA, Transformers ...

    Eaton V48M28T1516 Transformer, Dry Type, TP-1, 480 x 120/208V, 3PH, 15 kVA, 15 KVA, 3-Phase, 480 Delta Primary Volts - 208Y/120 Secondary Volts, NEMA 1, Energy Efficient, Energy Star labeled Transformer, Ventilated, 150 Degree C, Aluminum Windings, 60 Hz operation, Frame Size: FR939. For Outdoor use Weather Shield WS57. DOE 2016 Efficient.

    Get Price
  • 15 KVA Transformer Primary 240 x 480 Secondary 120/240 ...

    FEDERAL PACIFIC, Dry Type Transformer, Stock No. 11-9629, 1 Phase, KVA 15, Primary Voltage 240 x 480, Secondary Voltage 120/240, No Taps Taps, 115 ºC Temp Rating, Impedance Pct., 270 Lbs. Weight, 17.00 Inches Height, 13.12 Inches Depth, Catalog Number P2XLF21-15-N, New Price $880.00

    Get Price
  • Eaton - V48M22T1516, Dry Type - 15 KVA, Transformers ...

    Eaton V48M22T1516 15KVA, 3P, 480V, 240V, Energy Efficient Transformer 15 KVA, 3-Phase, 480 Delta Primary Volts - 240 Delta Secondary Volts with 120 Volt Lighting Tap, NEMA 1, Energy Efficient, Energy Star labeled Transformer, Ventilated, 150 Degree C, Aluminum Windings, 60 Hz operation, Frame Size: FR939. For Outdoors use Weather Shield WS57.

    Get Price
  • Square D (Schneider Electric) EE15S3H Dry-Type

    Shop Dry-Type Transformer, Energy Efficient, 1-Phase, 15 KVA, 240 X 480 Primary, 120/240V Secondary, NEMA 1 By Square D (Schneider Electric) (EE15S3H) At Graybar, Your Trusted Resource For Dry-Type Transformers And Other Square D (Schneider Electric) Products.

    Get Price
  • Dry Type Transformers - Siemens

    2021-9-13u2002·u2002DRY TYPE TRANSFORMERS NRCAN Rated General Purpose Transformers Industrial Type Copper Winding Selection a W = Wall mount F = Floor mount b Taps: Single phase: 15-250 kVA - 2 x FCAN, 2 x FCBN Three phase: 15-300 kVA - 2 x FCAN, 2 x FCBN All weights and dimensions are approximate and subject to change without notice.

    Get Price
  • Dry Type Transformers Full Line Catalog - Jefferson Electric

    2021-3-16u2002·u2002Single-Phase Ventilated 1-3 Single-Phase General Purpose Transformers – DOE Compliant 150°C Temperature Rise • Aluminum Windings • NEMA3R Enclosures Taps: 2 @ 2.5% FCAN & 4 @ 2.5% FCBN 240 x 480V — 120/240V kVA Catalog Number Enclosure Figure Height (A) inches Width (B) inches Depth (C) inches (D) inches (E) inches Est Ship Wgt Wiring ...

    Get Price
  • 15kva XFMR Calculation

    2007-8-3u2002·u2002I wanted to figure the size of a primary breaker for a 15kva transformer: 480v single phase primary to 120/240v single phase secondary, 15000 divided by 480 = 31.25 amps. Is this correct? The load draw would be around 55 amps, would a 30amp primary breaker be sufficiant for this transformer?

    Get Price
  • Sizing Guide for Dry Type Transformers - LynTec

    2010-12-10u2002·u2002Sizing Guide for Dry Type Transformers Single Phase Transformers Primary Voltage Main Breaker kVA Rating Primary Lugs Secondary Lugs 208V 80A 15 100A 100A 208V 150A 25 250A 250A 208V 200A 37.5 250A 250A 208V 225A 50 400A 400A 240V 80A 15 100A 100A 240V 150A 25 250A 250A 240V 200A 37.5 250A 250A 240V 225A 50 400A 400A Three Phase Transformers ...

    Get Price
Contact Us